Bioenergy
D. Baveli Bahmaei; Y. Ajabshirchy; Sh. Abdollahpour; S. Abdanan Mehdizadeh
Abstract
This research aims to optimize the mixing process in gas-lift anaerobic digesters of municipal sewage sludge since mixing and maintaining uniform contact between methanogenic bacteria and nutrients is essential. Wastewater municipal sludge sampling was performed at the Ahvaz West treatment plant (Chonibeh, ...
Read More
This research aims to optimize the mixing process in gas-lift anaerobic digesters of municipal sewage sludge since mixing and maintaining uniform contact between methanogenic bacteria and nutrients is essential. Wastewater municipal sludge sampling was performed at the Ahvaz West treatment plant (Chonibeh, Iran) during the summer of 2022. A Computational Fluid Dynamics (CFD) model was implemented to simulate, optimize, and confirm the simulation process using ANSYS Fluent software 19.0. The velocity of the inlet-gas into the digester was determined and a draft tube and a conical hanging baffle were added to the digester design. Different inlet-gas velocities were investigated to optimize the mixing in the digester. Furthermore, turbulence kinetic energy and other evaluation indexes related to the sludge particles such as their velocity, velocity gradient, and eddy viscosity were studied. The optimal inlet-gas velocity was determined to be 0.3 ms-1. The simulation results were validated using the Particle Image Velocimetry (PIV) method and the correlation between CFD and PIV contours was statistically sufficient (98.8% at the bottom corner of the digester’s wall). The results showed that the model used for simulating, optimizing, and verifying the simulation process is valid. It can be recommended for gas-lift anaerobic digesters with the following specifications: cylindrical tank with a height-to-diameter ratio of 1.5, draft tube-to-digester diameter ratio of 0.2, draft tube-to-fluid height ratio of 0.75, the conical hanging baffle distance from the fluid level equal to 0.125 of the fluid height, and its outer diameter-to-digester diameter of 2/3.
H. Ghasemi Mobtaker; Y. Ajabshirchi; S. F. Ranjbar; M. Matloobi
Abstract
Introduction Greenhouse is a structure which provides the best condition for the maximum plants growth during the cold seasons. In cold climate zones such as Tabriz province, Iran, the greenhouse heating is one of the most energy consumers. It has been estimated that the greenhouse heating cost is attributed ...
Read More
Introduction Greenhouse is a structure which provides the best condition for the maximum plants growth during the cold seasons. In cold climate zones such as Tabriz province, Iran, the greenhouse heating is one of the most energy consumers. It has been estimated that the greenhouse heating cost is attributed up to 30% of the total operational costs of the greenhouses. Renewable energy resources are clean alternatives that can be used in greenhouse heating. Among the renewable energy resources, solar energy has the highest potential around the world. In this regard, application of solar energy in greenhouse heating during the cold months of a year could be considerable. The rate of thermal energy required inside the greenhouse depends on the solar radiation received inside the greenhouse. Using a north brick wall in an east-west oriented greenhouse can increase the absorption of solar radiation and consequently reduces the thermal and radiation losses. Therefore, the main objective of the present study is to investigate the effect of implementing of a north wall on the solar radiation absorption and energy consumption of an east-west oriented single span greenhouse in Tabriz. Materials and Methods This study was carried out in Tabriz and a steady state analysis was used to predict the energy consumption of a single span greenhouse. For this purpose, thermal energy balance equations for different components of the greenhouse including the soil layer, internal air and plants were presented. For investigating the effect of the north wall on the energy consumption, the Ft and Fn parameters were used to calculate the radiation loss from the walls of the greenhouses. These factors were determined using a 3D–shadow analysis by Auto–CAD software. An east-west oriented single span greenhouse which has a north brick wall and is covered with a single glass sheet with 4 mm thickness was applied to validate the developed models. The measurements were carried out on a sunny winter day (November 30, 2015). The hourly variations of solar radiation on a horizontal surface were measured to calculate the total solar radiation received by the greenhouse using the Liu and Jordan equations. For heating of a greenhouse in nighttime, an electrical heater was used while an additional required energy was measured using a single phase meters. The inside and ambient temperatures of the air were recorded using SHT11 temperature sensors. A computer-based program of EES (engineering equations solver) was developed to solve the energy balance equations. Different statistical indicators were used to predict the accuracy of the presented models. Results and Discussion The obtained results showed that in winter months the greenhouse without the north brick wall can receive 14% more solar radiation than the greenhouse with a north brick wall. On the other hand, the use of a north wall in the greenhouses can reduce the radiation and thermal loss from north wall. To maintain the temperature at 25 °C in day-time and 15 °C in night-time, the additional required energy was calculated for greenhouse with and without north brick wall. The results indicated that the total energy requirement to keep the plants warm was 313.8 MJ in greenhouse without north brick wall and 210.8 MJ in greenhouse with the north brick wall. In other word, use of the north brick wall in the greenhouse can contribute to reduce energy consumption by 32%. Comparisons between the predicted and measured results showed a fair agreement for greenhouse energy requirements. The correlation coefficient and mean percentage error for this model were determined to be 0.79 and -2.34%, respectively. Due to the small values, the radiative exchange within greenhouse cover and the sky was neglected. Therefore, the results of the presented model showed fewer values in comparison with the experimental results. It can be concluded from the final results that a considerable amount of the incident radiation has been lost to the ambient by convection from the cover of the greenhouse (glass walls and north walls). Conclusion In the present study, the effect of north brick wall on solar radiation absorption and energy consumption of a single span greenhouse located in Tabriz was investigated. Results showed that use of north brick wall in an east-west oriented single span greenhouse leads to a reduction of 14% in solar radiation absorbed by the greenhouse. The results indicated that use of the north brick wall in the greenhouse can decrease energy consumption by 32%. There was a fair agreement between the experimental and theoretical results with the calculated correlation coefficient and mean percentage error of 0.79 and -2.34%, respectively.
M. Taki; Y. Ajabshirchi; S. F. Ranjbar; A. Rohani; M. Matloobi
Abstract
Introduction Controlling greenhouse microclimate not only influences the growth of plants, but also is critical in the spread of diseases inside the greenhouse. The microclimate parameters were inside air, greenhouse roof and soil temperature, relative humidity and solar radiation intensity. Predicting ...
Read More
Introduction Controlling greenhouse microclimate not only influences the growth of plants, but also is critical in the spread of diseases inside the greenhouse. The microclimate parameters were inside air, greenhouse roof and soil temperature, relative humidity and solar radiation intensity. Predicting the microclimate conditions inside a greenhouse and enabling the use of automatic control systems are the two main objectives of greenhouse climate model. The microclimate inside a greenhouse can be predicted by conducting experiments or by using simulation. Static and dynamic models are used for this purpose as a function of the metrological conditions and the parameters of the greenhouse components. Some works were done in past to 2015 year to simulation and predict the inside variables in different greenhouse structures. Usually simulation has a lot of problems to predict the inside climate of greenhouse and the error of simulation is higher in literature. The main objective of this paper is comparison between heat transfer and regression models to evaluate them to predict inside air and roof temperature in a semi-solar greenhouse in Tabriz University. Materials and Methods In this study, a semi-solar greenhouse was designed and constructed at the North-West of Iran in Azerbaijan Province (geographical location of 38°10′ N and 46°18′ E with elevation of 1364 m above the sea level). In this research, shape and orientation of the greenhouse, selected between some greenhouses common shapes and according to receive maximum solar radiation whole the year. Also internal thermal screen and cement north wall was used to store and prevent of heat lost during the cold period of year. So we called this structure, ‘semi-solar’ greenhouse. It was covered with glass (4 mm thickness). It occupies a surface of approximately 15.36 m2 and 26.4 m3. The orientation of this greenhouse was East–West and perpendicular to the direction of the wind prevailing. To measure the temperature and the relative humidity of the air, soil and roof inside and outside the greenhouse, the SHT 11 sensors were used. The accuracy of the measurement of temperature was ±0.4% at 20 °C and the precision measurement of the moisture was ±3% for a clear sky. We used these sensors in soil, on the roof (inside greenhouse) and in the air of greenhouse and outside to measure the temperature and relative humidity. At a 1 m height above the ground outside the greenhouse, we used a pyranometre type TES 1333. Its sensitivity was proportional to the cosine of the incidence angle of the radiation. It is a measure of global radiation of the spectral band solar in the 400–1110 nm. Its measurement accuracy was approximately ±5%. Some heat transfer models used to predict the inside and roof temperature are according to equation (1) and (5): Results and Discussion Results showed that solar radiation on the roof of semi-solar greenhouse was higher after noon so this shape can receive high amounts of solar energy during a day. From statistical point of view, both desired and predicted test data have been analyzed to determine whether there are statistically significant differences between them. The null hypothesis assumes that statistical parameters of both series are equal. P value was used to check each hypothesis. Its threshold value was 0.05. If p value is greater than the threshold, the null hypothesis is then fulfilled. To check the differences between the data series, different tests were performed and p value was calculated for each case. The so called t-test was used to compare the means of both series. It was also assumed that the variance of both samples could be considered equal. The variance was analyzed using the F-test. Here, a normal distribution of samples was assumed. The results showed that the p values for heat model in all 2 statistical factors (Comparison of means, and variance) is lower than regression model and so the heat model did not have a good efficient to predict Tri and Ta. RMSE, MAPE, EF and W factor was calculated for to models. Results showed that heat model cannot predict the inside air and roof temperature compare to regression model. Conclusion This article focused on the application of heat and regression models to predict inside air (Ta) and roof (Tri) temperature of a semi-solar greenhouse in Iran. To show the applicability and superiority of the proposed approach, the measured data of inside air and roof temperature were used. To improve the output, the data was first preprocessed. Results showed that RMSE for heat model to predict Ta and Tri is about 1.58 and 6.56 times higher than this factor for regression model. Also EF and W factor for heat model to predict above factors is about 0.003 and 0.041, 0.013 and 0.220 lower than regression model respectively. We propose to use Artificial Neural Network (ANN) and Genetic Algorithm (GA) to predict inside variables in greenhouses and compare the results with heat and regression models.
R. Rahimzadeh; Y. Ajabshirchi; Sh. Abdollahpour; A. Sharifi Malvajerdi; N. Sartipi; A. Mohammadi
Abstract
Introduction
Direct planting becomes more common in the recent years, because it conserves soil and water as well as it saves energy and time. However, this technology needs special implements such as seed planter. Given that direct planting is practiced in undisturbed lands, so it was needed to design ...
Read More
Introduction
Direct planting becomes more common in the recent years, because it conserves soil and water as well as it saves energy and time. However, this technology needs special implements such as seed planter. Given that direct planting is practiced in undisturbed lands, so it was needed to design a special furrow opener. In order to obtain a suitable furrow opener this experiment was conducted in rain-fed Agricultural Research Institute in Maragheh.
Materials and Methods
Most of seed planters that are used for cultivation in rain fed conditions are equipped by hoe-type furrow opener. Hoe-type furrow openers have good penetration in hard and dry soils. However, they do not have the ability for direct planting. Hoe-type furrow opener was chosen as a model. Then by changing the geometric form of the depth to width ratio (d/w), the two openers were designed. In the first design, which was called O1 two wings and a narrow blade acting as a coulter were added in front of the hoe-type furrow opener. In the second design, which was called O2, in addition to the O1 modification, furrow opener width was decreased and a disk blade was added for seed sowing (Fig. 1).
The performance of O1 and O2 openers were compared with the conventional hoe-type furrow opener (check) in soil bin and in field conditions. At three different forward speeds (1, 1.5 and 2 m.s-1) with 3 replications, the effects of the openers designs of vertical and horizontal soil forces were evaluated in soil-bin conditions. In order to evaluate the performance of the furrow opener in field conditions, an experiment was conducted using a split plot design based on RCBD at 4 replications. Furrow openers formed the main plots and forward speeds formed the sub plots. Each plot size was 22 meters long in two rows for each treatment. After germination of wheat crop, the numbers of seedlings in two rows were counted (along a one meter). After crop maturity, all plots were harvested by hand and grain and biological yield was measured. ANOVA test, uniformity test and mean comparison were conducted by using Genstat software.
Results and Discussion
The soil bin test results showed that opener design and forward speed both have significant influences on the horizontal force (p<0.01). Horizontal force was increased with increasing of forward speeds. The same result was reported by Wheeler and Godwin, 1996 and Astafford, 1979. The lowest horizontal force (average 1.66 kN) occurred at 1 m.s-1 and the highest (average 1.94 kN) occurred at 2 m.s-1 forward speeds. Horizontal force increased in O2 (2.8%) and decreased in O1 (3.4%) compared with the control (average 1.77 kN). Moreover, openers had significant influence on the vertical force (p<0.01). Vertical force values were negative in O1 (average -0.05 kN) and O2 (average -0.07 kN) in comparison with positive value in the control (average +0.01 kN). The effect of forward speed on vertical force was not statistically significant. The field results showed that there were significant differences among the openers in the numbers of seedling, grain and biological yield (p<0.01). The O2 opener (with the average of 48 seedlings per one meter row) had 33% and 24% more seedlings in comparison with O1 and check furrow openers, respectively. Probably, using dick bald in O2 design leads to increased seed germination. Increasing of seed germination by using disk furrow opener as an advantage is reported by Kushwaha and Foster, 1993. The O2 furrow opener would also increase grain yield about 36% compared with both O1 and check furrow openers.
Conclusions
It can be concluded that the newly designed furrow opener (O2) could improve the energy efficiency with increasing crop yield. Hence, O2 furrow opener could be recommended for direct planting in rain-fed farming.
N. Eqra; Y. Ajabshirchi; M. Sarshar; S. S. Alavi
Abstract
Bioethanol production from agricultural residues is one of the promising methods. Pretreatment is the most important step in this type of bioethanol production. In this study, the saccharification percentage of sugarcane bagasse was investigated after two types of pretreatments including ozone steaming ...
Read More
Bioethanol production from agricultural residues is one of the promising methods. Pretreatment is the most important step in this type of bioethanol production. In this study, the saccharification percentage of sugarcane bagasse was investigated after two types of pretreatments including ozone steaming and microwave. Microwave pretreatment was studied with two factors of microwave radiation (170, 450, and 850 w) and microwave duration (2, 6, and 10 min). The ozonolysis (ozone steaming) pretreatment was surveyed with two factors of moisture content of bagasse (30, 40, and 50%) and ozonolysis time (1.5, 2.5, 3.5, and 4.5 hr). After hydrolysis, the Saccharification percentage of sugarcane bagasse increased to 57.2% and 67.06% with microwave and ozonolysis pretreatments, respectively; compare to 20.85% in non-ozonated bagasse. It can be concluded that the ozonolysis is the most effective pretreatment regarding to saccharification percentage of sugarcane bagasse.
M. Taki; Y. Ajabshirchi; R. Abdi; M. Akbarpour
Abstract
In this research energy efficiency for greenhouse cucumber production in Shahreza township located in Esfahan province using data envelopment analysis (DEA) technique was studied. In this study, data were obtained from 25 randomize active vegetable greenhouses from 60 greenhouses in Shahreza township ...
Read More
In this research energy efficiency for greenhouse cucumber production in Shahreza township located in Esfahan province using data envelopment analysis (DEA) technique was studied. In this study, data were obtained from 25 randomize active vegetable greenhouses from 60 greenhouses in Shahreza township and villages environs. The results showed that the highest and lowest consumed energy were related to fuel and water inputs with 47% and 1.2% respectively. The results of data envelopment analysis showed in CCR and BCC models 24% and 36% of farmers were efficient and the others were inefficient. Mean technical efficiency, net technical efficiency and scale efficiency were calculated as 90.37, 95.09 94.6 respectively. Also technical efficiency of inefficiency units in CCR model was 87% that shows13% of total energy input could be saved with upgrade efficiency in these units. In this research, total saved and unsaved energy related to fuel consumption.
Y. Ajabshirchi; M. Taki; R. Abdi; A. Ghobadifar; I. Ranjbar
Abstract
In this research energy efficiency for dry wheat production in three levels including 0.1 up to2, 2.1 up to 5 and over 5.1 hectares for the farming year 2008-2009 in Silakhor plain located in Borujerd and Dorud divisions of Lorestan province was studied using data envelopment analysis (DEA) technique. ...
Read More
In this research energy efficiency for dry wheat production in three levels including 0.1 up to2, 2.1 up to 5 and over 5.1 hectares for the farming year 2008-2009 in Silakhor plain located in Borujerd and Dorud divisions of Lorestan province was studied using data envelopment analysis (DEA) technique. The results showed that the input energy for seed, fertilizer and pesticides had the highest levels of energy consumption and the share of that in each studied level were 63.63, 56 and 54.07 percent respectively. The results of data envelopment analysis showed that the average of energy efficiency levels were 82, 78 and 68 percent, respectively. First level, that consumes more input energy than other two studied levels, had highest energy efficiency, because in this level output yield were more than other levels. Technical efficiency of inefficiency units in CRS model in three levels is 79%, 77% and 66% respectively. This issue indicates that 21, 23 and 34 of total energy input could be saved with upgrade efficiency in these units. All wrong using and also all share of total saved energy in three levels related to grain, fertilizer and pesticides and then fuel consumption.