<ArticleTitle>The Effect of Vegetation Coverage and Greenhouse Area on the Performance of an Earth-to-Air Heat Exchanger in Cooling Mode of Greenhouse</ArticleTitle>
<VernacularTitle>تأثیر سطح گلخانه و درصد پوشش گیاهی برکارآیی مبدل زمین به هوا در سرمایش گلخانه</VernacularTitle>
			<FirstPage>16</FirstPage>
			<LastPage>23</LastPage>
			<ELocationID EIdType="pii">25791</ELocationID>
			
<ELocationID EIdType="doi">10.22067/jam.v3i1.19709</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>محسن</FirstName>
					<LastName>محمدی مقرب</LastName>
<Affiliation>دانشگاه فردوسی مشهد</Affiliation>

</Author>
<Author>
					<FirstName>محمد حسین</FirstName>
					<LastName>عباسپورفرد</LastName>
<Affiliation>دانشگاه فردوسی مشهد</Affiliation>
<Identifier Source="ORCID">0000-0002-5575-5115</Identifier>

</Author>
<Author>
					<FirstName>مرتضی</FirstName>
					<LastName>گلدانی</LastName>
<Affiliation>دانشگاه فردوسی مشهد</Affiliation>
<Identifier Source="ORCID">0000-0002-2547-8014</Identifier>

</Author>
<Author>
					<FirstName>باقر</FirstName>
					<LastName>عمادی</LastName>
<Affiliation>دانشگاه فردوسی مشهد</Affiliation>
<Identifier Source="ORCID">0000-0002-3296-1119</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
		    <Abstract>The underground temperature at a depth of about three to four meters is almost constant during the year. As a result in summer the underground is cooler than the ambient temperature. This potential is considered for greenhouse cooling by using an Earth-to-Air Heat Exchanger (EAHE). In this research the effects of two parameters were investigated: a) the area of greenhouse in three levels of 9, 18, 27 m2 and b) the percent of vegetation coverage inside the greenhouse in three levels of 0%, 50%, 100% on the performance of EAHE. The experimental design was factorial experiment in a randomized complete block design. The parameters of greenhouse’s inside temperature, thermal energy exchange and coefficient of performance (COP) were considered in cooling mode. As one of the remarkable results it was observed that the closed loop utilization of the system was infeasible in cooling mode. This was mainly due to the occurrence of vapor distillation inside the underground pipes and hence the blockages of the air flow. Also the effect of area and the percent of vegetation coverage were significant on the performance of EAHE. The highest average temperature difference between the temperature of testimonial greenhouse and the temperature of greenhouse was observed in treatment of 100% vegetation coverage and 9 m2 floor area which was measured as 9.6°C. The least average temperature difference in the treatment without vegetation coverage and 27 m2 floor area was measured as 5.2 °C. Considering thermal energy exchange in cooling greenhouse with open loop, the best treatment determined for EAHE in this research was the one with 9 m2 floor area and 100% of vegetation coverage.</Abstract>
			<OtherAbstract Language="FA">دما در طول سال در عمق 3 تا 4 متری زمین تقریباً ثابت است، در نتیجه تابستان دمای زیر زمین کمتر از دمای محیط بوده و این پتانسیل می-تواند برای سرمایش گلخانه با استفاده از سامانه مبدل زمین به هوا مورد استفاده قرار گیرد. در این تحقیق به‌منظور بررسی کارایی این سامانه بر سرمایش گلخانه، اثر دو پارامتر مساحت کف گلخانه در سه سطح 9، 18 و 27 مترمربع و درصد پوشش گیاهی گلخانه در سه سطح صفر، 50 و 100 درصد بر دمای داخل گلخانه مورد بررسی قرار گرفت. طرح آزمایشی مورد استفاده آزمون فاکتوریل بر پایه بلوک های کاملاً تصادفی می باشد. پارامترهای دمای دورن گلخانه، انرژی حرارتی مبادله شده و ضریب عملکرد مورد بررسی قرار گرفتند. از نتایج قابل توجه در این تحقیق این است که در حالت سرمایش به‌دلیل بروز پدیده تقطیر در داخل لوله ها امکان استفاده از سیکل بسته وجود ندارد. همچنین اثر مساحت و درصد پوشش گیاهی بر عملکرد سامانه معنی دار بود. به‌طوری‌که بیشترین میانگین اختلاف دمایی بین دمای گلخانه شاهد و دمای گلخانه در تیمار پوشش گیاهی100 درصد و مساحت کف 9 مترمربع و برابر 6/9 درجه سانتی‌گراد و کمترین میانگین اختلاف دمایی در تیمار بدون پوشش گیاهی و مساحت کف 27 مترمربع و برابر 2/5 درجه سانتی‌گراد به دست آمد. با درنظر گرفتن میانگین انرژی حرارتی مبادله شده در هر تیمار برای حالت سرمایش با سیکل باز بهترین تیمار برای سامانه استفاده شده در این تحقیق، تیمار با مساحت کف 9 مترمربع و 100 درصد پوشش گیاهی تعیین شد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">اختلاف دما</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">انرژی مبادله شده</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">سرمایش</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">سیستم مبدل زمین به هوا</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">گرمایش</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jame.um.ac.ir/article_25791_74b72ae2ee96f9be8900a13e80fb63ac.pdf</ArchiveCopySource>
</Article>
</ArticleSet>