Abstract

Introduction
Controlling greenhouse microclimate not only influences the growth of plants, but also is critical in the spread of diseases inside the greenhouse. The microclimate parameters were inside air, greenhouse roof and soil temperature, relative humidity and solar radiation intensity. Predicting the microclimate conditions inside a greenhouse and enabling the use of automatic control systems are the two main objectives of greenhouse climate model. The microclimate inside a greenhouse can be predicted by conducting experiments or by using simulation. Static and dynamic models are used for this purpose as a function of the metrological conditions and the parameters of the greenhouse components. Some works were done in past to 2015 year to simulation and predict the inside variables in different greenhouse structures. Usually simulation has a lot of problems to predict the inside climate of greenhouse and the error of simulation is higher in literature. The main objective of this paper is comparison between heat transfer and regression models to evaluate them to predict inside air and roof temperature in a semi-solar greenhouse in Tabriz University.

Materials and Methods
In this study, a semi-solar greenhouse was designed and constructed at the North-West of Iran in Azerbaijan Province (geographical location of 38°10′ N and 46°18′ E with elevation of 1364 m above the sea level). In this research, shape and orientation of the greenhouse, selected between some greenhouses common shapes and according to receive maximum solar radiation whole the year. Also internal thermal screen and cement north wall was used to store and prevent of heat lost during the cold period of year. So we called this structure, ‘semi-solar’ greenhouse. It was covered with glass (4 mm thickness). It occupies a surface of approximately 15.36 m2 and 26.4 m3. The orientation of this greenhouse was East–West and perpendicular to the direction of the wind prevailing. To measure the temperature and the relative humidity of the air, soil and roof inside and outside the greenhouse, the SHT 11 sensors were used. The accuracy of the measurement of temperature was ±0.4% at 20 °C and the precision measurement of the moisture was ±3% for a clear sky. We used these sensors in soil, on the roof (inside greenhouse) and in the air of greenhouse and outside to measure the temperature and relative humidity. At a 1 m height above the ground outside the greenhouse, we used a pyranometre type TES 1333. Its sensitivity was proportional to the cosine of the incidence angle of the radiation. It is a measure of global radiation of the spectral band solar in the 400–1110 nm. Its measurement accuracy was approximately ±5%. Some heat transfer models used to predict the inside and roof temperature are according to equation (1) and (5):
Results and Discussion
Results showed that solar radiation on the roof of semi-solar greenhouse was higher after noon so this shape can receive high amounts of solar energy during a day. From statistical point of view, both desired and predicted test data have been analyzed to determine whether there are statistically significant differences between them. The null hypothesis assumes that statistical parameters of both series are equal. P value was used to check each hypothesis. Its threshold value was 0.05. If p value is greater than the threshold, the null hypothesis is then fulfilled. To check the differences between the data series, different tests were performed and p value was calculated for each case. The so called t-test was used to compare the means of both series. It was also assumed that the variance of both samples could be considered equal. The variance was analyzed using the F-test. Here, a normal distribution of samples was assumed. The results showed that the p values for heat model in all 2 statistical factors (Comparison of means, and variance) is lower than regression model and so the heat model did not have a good efficient to predict Tri and Ta. RMSE, MAPE, EF and W factor was calculated for to models. Results showed that heat model cannot predict the inside air and roof temperature compare to regression model.

Conclusion
This article focused on the application of heat and regression models to predict inside air (Ta) and roof (Tri) temperature of a semi-solar greenhouse in Iran. To show the applicability and superiority of the proposed approach, the measured data of inside air and roof temperature were used. To improve the output, the data was first preprocessed. Results showed that RMSE for heat model to predict Ta and Tri is about 1.58 and 6.56 times higher than this factor for regression model. Also EF and W factor for heat model to predict above factors is about 0.003 and 0.041, 0.013 and 0.220 lower than regression model respectively. We propose to use Artificial Neural Network (ANN) and Genetic Algorithm (GA) to predict inside variables in greenhouses and compare the results with heat and regression models.

Keywords

1. Abdel Ghany, A. M. and I. M. Helal. 2011. Solar energy utilization by a greenhouse: General relations. Renewable Energy 36: 189-196.
2. Abdi R., M. Taki, and M. Akbarpour. 2012. An Analysis of Energy input-output and Emissions of Greenhouse Gases from Agricultural Productions. International Journal of Natural and Engineering Sciences 6 (3): 73-79.
3. Alonso, J. P., M. P. Garcia, M. P. Romera, and A. J. C. Ferre. 2012. Performance analysis and neural modeling of a greenhouse integrated photovoltaic system. Renewable and Sustainable Energy Reviews 16: 4675-4685.
4. Banaeian, N., M. Omid, and H. Ahmad. 2011. Application of Data Envelopment Analysis to Evaluate Efficiency of Commercial Greenhouse Strawberry. Research Journal of Applied Sciences, Engineering and Technology 3 (3): 185-193.
5. Boaventura, L., C. Couto, and A. E. B. Ruano. 2000. A greenhouse climate multivariable predictive controller, Acta Horticulturae 534: 269-276.
6. Buchholz, M., R. Buchholz, and P. Jochum. 2006. Temperature and humidity control in the Watergy greenhouse. Acta Horticulturae 2: 719-731.
7. Canakci, M., and I. Akinci. 2006. Energy use pattern analyses of greenhouse vegetable production. Energy 31 (8-9): 1243-1256.
8. Chandra, P. 1976. Predicting the effects of greenhouse orientation and insulation on energy conservation. Unpublished M.Sc. thesis. Department of Agricultural Engineering, University of Manitoba, Winnipeg, Manitoba, Canada.
9. Chandra, P., and L. D. Albright. 1978. Analytical determination of the effects of using night curtains in greenhouses Paper ASAE.
10. Dariouchy, A., E. Aassif, K. Lekouch, L. Bouirden, and G. Maze. 2009. Prediction of the intern parameters tomato greenhouse in a semi-arid area using a time-series model of artificial neural networks. Measurement 42: 456-463.
11. Du, J., P. Bansal, and B. Huang. 2012. Simulation model of a greenhouse with a heat-pipe heating system. Applied Energy 93: 268-276.
12. Ferreira, P. M., E. A. Faria, and A. E. Ruano. 2002. Neural network models in greenhouse air temperature prediction. Neurocomputing 43 (1-4): 51-75.
13. Fuller, R., C. Meyer, and P. Sale. 1987. Validation of a dynamic model for predicting energy use in greenhouse. Journal of Agricultural Engineering 38: 1-14.
14. He, F., and C. Ma. 2010. Modeling greenhouse air humidity by means of artificial neural network and principal component analysis. Computers and Electronics in Agriculture 71S: S19-S23.
15. Heuvelink, E., and M. Bakker. 2008. Climate and yield in a closed greenhouse. Acta Horticulture 801: 1083-1092.
16. Hoes, H., and J. Desmedt. 2008. The GESKAS project, closed greenhouse as energy source and optimal growing environment. Acta Horticulture 801: 1355-1362.
17. Hollmuller, P., and B. Lachal. 1998. TRNSYS compatible moist air hypocaust model. Final report. Project number 19507. University De Geneve.
18. Joudi, K. A., and A. Farhan A. 2015. A dynamic model and an experimental study for the internal air and soil temperatures in an innovative greenhouse. Energy conversion and management 91: 76-82.
19. Linker, R., and I. Seginer. 2004. Greenhouse temperature modeling: a comparison between sigmoid neural networks and hybrid models. Mathematics and Computers in Simulation 65: 19-29.
20. Linker, R., I. Seginer and P.O. Gutman. 1998. Optimal CO2 control in a greenhouse modeled with neural networks. Computers and Electronics in Agriculture 19: 289-310.
21. McCune, W. F., and D. Stipe .1960. Electric heating for plastic greenhouses, a summary of progress report to the Texas Farm Electrification Committee. Texas A&M University, College Station, TX: Department of Agricultural Engineering.
22. Morris, L. G. 1956. Some aspect of the control of plant environment. Journal of agricultural engineering research 1: 156-166.
23. Nayak, S., and G. N. Tiwari. 2006. Energy metrics of photovoltaic/thermal and earth air heat exchanger integrated greenhouse for different climatic conditions of India. Applied Energy 87: 2984-2993.
24. Ntinas, G. K., V. P. Fragos, and C. H. N. Martzopoulou. 2014. Thermal analysis of a hybrid solar energy saving system inside a greenhouse. Energy Conversion and Management 81: 428-439.
25. Omid, M., F. Ghojabeige, M. Delshad, and H. Ahmadi. 2011. Energy use pattern and benchmarking of selected greenhouses in Iran using data envelopment analysis. Energy conversion and Management 52: 153-162.
26. Panwar, N. L., S. C. Kaushik, and S. Kothari. 2011. Solar greenhouse an option for renewable and sustainable farming. Renewable and Sustainable Energy Reviews 15: 3934-3945.
27. Rohani, A., M. H. Abbaspour-Fard and S. Abdolahpour. 2011. Prediction of tractor repair and maintenance costs using artificial neural network. Expert Sys. Applications 38: 8999-9007.
28. Shukla, A., G. N. Tiwari, and M. S. Sodha. 2006. Thermal modeling for greenhouse heating by using thermal curtain and an earth–air heat exchanger. Building and Environment 41 (7): 843-850.
29. Shukla, M. K., R. Lal, and P. Unkefer. 2003. Experimental evaluation of infiltration models for different land use and soil management systems. Soil Science 168 (3): 178-191.
30. Simpkins, J. C., D. R. Mears, and W. J. Robert. 1979. Reducing closes in polyethylene covered greenhouses. ASABE 19 (4): 714-719.
31. Singh, R. D., and G. N. Tiwari. 2010. Energy conservation in the greenhouse system: A steady state analysis. Energy 35: 2367-2373.
32. Taki, M., R. Abdi, M. Akbarpour, and H. G. Mobtaker. 2013. Energy inputs – yield relationship and sensitivity analysis for tomato greenhouse production in Iran. Agric Eng Int: CIGR Journal 15 (1): 59-67.
33. Taki, M., Y. Ajabshirchi, S. F. Ranjbar, A. Rohani, and M. Matloobi. 2016. Heat transfer and MLP neural network models to predict inside environment variables and energy lost in a semi-solar greenhouse. Energy and Buildings 110: 314-329.
34. Tiwari G. N., M. A. Akhtar, A. Shukla, and M. Emran Khan. 2006. Annual thermal performance of greenhouse with an earth–air heat exchanger: An experimental validation. Renewable Energy 31: 2432-2446.
35. Vadiee, A. 2011. Energy Analysis of the Closed Greenhouse Concept-Toward one Sustainable Energy Pathway. KTH School of Industrial Engineering and Management Department of Energy Technology Division of Heat and Power Technology SE-100 44 STOCKHOLM.
36. Vadiee, A., and V. Martin. 2012. Energy management in horticultural applications through the closed greenhouse concept, state of the art. Renewable and Sustainable Energy Reviews 16: 5087-5100.
37. Vadiee, A., and V. Martin. 2013. Energy analysis and thermo economic assessment of the closed greenhouse – The largest commercial solar building. Applied Energy 102: 1256-1266.
38. Van Ooteghem, R. J. C. 2007. Optimal Control Design for a Solar Greenhouse, Systems and Control. Wageningen: Wageningen University.
39. Van Straten, G., G. Van Willigenburg, E. Van Henten, and R. Van Oothghem. 2011. Optimal control of greenhouse cultivation. CRC press, Taylor and Francis, New York.
40. Walker, J. N. 1965. Predicting temperatures in ventilated greenhouse. Transactions of the American society of agricultural angineers 8 (3): 445-448.
41. Willits, D., P. Chandra, and M. Peet. 1985. Modeling solar energy storage system for greenhouse. Journal of Agricultural Engineering 32: 73-79.
42. Willmott, C., J. Ackleson, S. G. Davis, R. E. Feddema, J. J. Klink, K. M. Legates, D. R. Donnell, and C. M. Rowe. 1985. Statistics for the evaluation and comparison of models. Journal of Geophysical Research 90: 8995-9005.
43. Zabeltitz, C. V. 2011. Integrated Greenhouse Systems for Mild Climates. Springer-Verlag Berlin Heidelberg.
CAPTCHA Image